Single Phase Motor:- 'Delta'
Single Phase Motor are backed by the design and manufacturing skills
acquired by the company through its long experience in this line.
| Range : |
| Hp / Kw |
: |
0.25 / 0.18 kw to 3 hp / 2.2 kw |
| Frame |
: |
B56,100,112,132 |
| Syn.RPM |
: |
3000, 1500 |
| Duty |
: |
S1 |
| Insulation |
: |
B, E, F |
| Protection |
: |
SPDP, TEFC |
Standard of Manufacture:
| BS 2048 Part I |
: |
For dimensions of 0.25 hp to I hp motors. |
| IS 996 & IS 1231 |
: |
For dimensions above 1 hp to 3 hp motors |
| BS 5000 Part 11 & IS 996 |
: |
For performance. |
| Voltage & Frequency |
:
|
Motors
are designed for std. 2306% Volts, 50 HzÃ3% supply.
Motors with different voltage (110 Volts) and 60 Hz frequency are
available on request.
|
|
|
Motor Frame
|
:
|
0.25
hp to I hp motors are normally supplied in M.S. sheetmetal febricated
body (Frame size B56) with screen protected endshields. However, the
above motors can be supplied in Totally Enclosed Fan Cooled (TEFC) C.I.
body, if required. Above 1 hp to 3hp the motors are supplied in TEFC
C.I.body of 100,112,132 frame.
|
| Mountings |
:
|
Foot mounted , Flange mounted or combination of both. |
| Bearings & Lubrication |
:
|
All the motors are supplied with C3
ball bearings. Bearing housings are so designed that grease is retained
in housing and are adequately protected against pentration of dust,
dirt and damp. All bearings are fully charged with lithium base grease
at the time of assembly and no further lubrication is required for two
years normal running. However, motors are also available with pre
lubricated sealed bearings.
|
| Centrifugal Gear |
:
|
The
specially designed electronic starting switch fitted in terminal box. Motors can be manufactured and supplied with permanent split
phase, capacitor start and run also i.e. without centrifugal gear and
open circuiting switch.
|
| Open Circuiting Switch |
:
|
The
open circuiting switch operated by the centrifugal gear has bimetal
contacts of silver and copper and mounted on high quality phosper
bronze supporting arm. |
| Winding Protection |
:
|
Embedded of PTC thermisters in the stator windings is feasible on request. |
| Running |
:
|
The careful construction and special design ensure quiet running of the motor. |
|